In-operando FT-IR spectroscopy of electrolyte decomposition in lithium-ion batteries

Shelton, Austin
Saqib, Najmus
Porter, Jason M.
Citations
Altmetric:
Advisor
Editor
Date
2017-07
Date Issued
Date Submitted
Keywords
Research Projects
Organizational Units
Journal Issue
Embargo Expires
Abstract
One of the major problems of Li-ion batteries is the decomposition of electrolyte at elevated temperatures. In situ FT-IR spectroscopy can be used to study the health of the electrolyte in Li-ion cells. We used an ATR FT-IR spectro-electrochemical cell to observe thermal decomposition of LiPF6 EC/DEC electrolyte in a LiCoO2 coin cell. Results show that at 70 ℃, several infrared absorption peaks were irreversibly lost. This led to a significant degradation of the electrochemical performance of the battery.