Show simple item record

dc.contributor.advisorPei, Shiling
dc.contributor.authorKordziel, Steven
dc.date.accessioned2018-05-31T15:31:53Z
dc.date.accessioned2022-02-03T13:14:58Z
dc.date.available2018-05-31T15:31:53Z
dc.date.available2022-02-03T13:14:58Z
dc.date.issued2018
dc.identifierKordziel_mines_0052N_11514.pdf
dc.identifierT 8511
dc.identifier.urihttps://hdl.handle.net/11124/172342
dc.descriptionIncludes bibliographical references.
dc.description2018 Spring.
dc.description.abstractMass timber products have shown promise as an innovative alternative to conventional framing systems for use in tall wood buildings, but this new trend in design and construction poses concerns for the long-term durability of the products. A major challenge that classically faces timber products is the threat of moisture-induced mold and decay fungi, which are a heightened concern in mass timber buildings exposed to the environment for extended duration during construction. Consequently, it is important to understand the hygric and thermal (hygrothermal) conditions that mass timber products can experience in multi-story constructions and to be able to quantify the behavior of the products for their suitable design and implementation. An eight-story mass timber building located in Portland, Oregon was chosen for this study and was instrumented for moisture content monitoring through its production, construction, and in-situ use. Record breaking precipitation levels occurred during the building’s construction and while dimension lumber and glulam products subsequently dried to acceptable levels, cross laminated timber products (CLT) dried more slowly. These measurements have an observed bias and the decay risk for the products is inconclusive. Samples of CLT used in the building were characterized for hygrothermal properties and integrated into WUFI, a simulation software, for analysis of the building. The software showed limitations for correctly simulating the behavior of CLT in isolated lab experiments and therefore a re-calibration was performed for accurate simulation. Preliminary on-site simulation results provide a decent approximation of observed data despite its high variance, but drying rate predicted by the program is lower than what was measured.
dc.format.mediumborn digital
dc.format.mediummasters theses
dc.languageEnglish
dc.language.isoeng
dc.publisherColorado School of Mines. Arthur Lakes Library
dc.relation.ispartof2018 - Mines Theses & Dissertations
dc.rightsCopyright of the original work is retained by the author.
dc.subjectcross laminated timber
dc.subjecthygrothermal
dc.subjectWUFI
dc.subjectglulam
dc.subjectCLT
dc.subjectmass timber
dc.titleStudy of moisture conditions in a multi-story mass timber building through the use of sensors and WUFI hygrothermal modeling
dc.typeText
dc.contributor.committeememberTabares-Velasco, Paulo Cesar
dc.contributor.committeememberIllangasekare, T. H.
thesis.degree.nameMaster of Science (M.S.)
thesis.degree.levelMasters
thesis.degree.disciplineCivil and Environmental Engineering
thesis.degree.grantorColorado School of Mines


Files in this item

Thumbnail
Name:
Kordziel_mines_0052N_11514.pdf
Size:
3.450Mb
Format:
PDF

This item appears in the following Collection(s)